Call 07942551685 80% Response Rate

Send Enquiry

our range

Fire Extinguisher Refilling Service

Leading Wholesale Trader of fire extinguisher refilling service from Surat.

Fire Extinguisher Refilling Service

  • Fire Extinguisher Refilling Service
  • Fire Extinguisher Refilling Service
  • Fire Extinguisher Refilling Service
  • Fire Extinguisher Refilling Service
  • Fire Extinguisher Refilling Service
  • Fire Extinguisher Refilling Service
  • Fire Extinguisher Refilling Service
  • Fire Extinguisher Refilling Service
  • Fire Extinguisher Refilling Service
  • Fire Extinguisher Refilling Service
  • Fire Extinguisher Refilling Service
  • Fire Extinguisher Refilling Service
  • Fire Extinguisher Refilling Service
Fire Extinguisher Refilling Service
Get Best Quote
Rs 400  / PiecePrice on Request

Minimum Order Quantity: 10 Piece

Product Brochure

Fire Extinguisher TypeCo2
Cylinder Capacity6 Kg
Service TypeFire Extinguisher Refilling Service
LocationWorldwide
Service ProviderAmeen Ehs Hub
UsageFor Fire Safety

IS 2190 is the Indian Standard for the Selection, Installation, and Maintenance of First-Aid Fire Extinguishers. It outlines the procedures for refilling and servicing fire extinguishers to ensure they function effectively in case of a fire emergency. Below are the key requirements related to fire extinguisher refilling and servicing as per IS 2190

🔥 Fire Extinguisher Refilling & Services as per IS 2190 🔥 1. General Requirements for Servicing & Refilling

✅ Fire extinguishers must be serviced at least once a year by a competent person.
✅ Only approved refilling agents and spare parts must be used.
✅ Hydrostatic pressure testing must be done at prescribed intervals.
✅ A detailed record of maintenance and refilling must be kept.

2. Refilling Frequency (As per IS 2190)
Type of Extinguisher Refilling Frequency
Water (Gas Cartridge) Every 3 years
Water (Stored Pressure) Every 3 years
Foam (Mechanical) Every 3 years
Dry Powder (Cartridge/Stored Pressure) Every 3 years
Carbon Dioxide (CO₂) Every 5 years
Clean Agent As per manufacturer’s guidelines
3. Hydrostatic Pressure Testing Schedule
Type of Extinguisher Testing Interval
Water, Foam, Powder Every 3 years
CO₂ Cylinder Every 5 years
4. Steps for Refilling Fire Extinguishers

🔹 Visual Inspection: Check for damage, corrosion, leaks, and tampering.
🔹 Discharge Test: Ensure the extinguisher is empty before refilling.
🔹 Cleaning: Remove residual extinguishing agent and clean internal parts.
🔹 Refilling: Use the correct extinguishing agent as per the manufacturer’s specifications.
🔹 Reassembly & Sealing: Reassemble the extinguisher, ensuring all components are in place.
🔹 Hydrostatic Testing: If required, perform pressure testing before recharging.
🔹 Labeling & Tagging: Update the service tag with the date of refilling, next due date, and technician details.
🔹 Final Inspection & Handover: Ensure proper working condition before returning to service.

5. Key Compliance Points

✅ Extinguishers must be maintained by trained personnel.
✅ Ensure IS-marked refilling materials are used.
✅ Pressure gauges and safety valves should be checked.
✅ Non-functional extinguishers should be replaced immediately.

 



Additional Information:

  • Item Code: 38130000
  • Production Capacity: 100%
  • Delivery Time: 3 DAYS
  • Packaging Details: ### **Packaging Details for Fire Extinguisher Refilling Materials** 🚒📦 When refilling fire extinguishers as per **IS 2190:2010**, the extinguishing agents must be packaged, stored, and transported safely. Below are the **packaging guidelines** for different refilling materials: --- ### **1. Dry Chemical Powder (DCP) – ABC & BC Type** ✅ **Packaging:** Sealed HDPE (High-Density Polyethylene) bags or moisture-resistant drums. ✅ **Standard Packaging Sizes:** 5 kg, 10 kg, 25 kg, 50 kg, and 100 kg bags/drums. ✅ **Storage Condition:** Keep in a dry place, away from direct sunlight and moisture. ✅ **Shelf Life:** Generally 5 years (check manufacturer’s specifications). --- ### **2. Carbon Dioxide (CO₂) Gas** ✅ **Packaging:** Stored in high-pressure seamless steel cylinders. ✅ **Cylinder Capacity:** 2 kg, 3 kg, 4.5 kg, 6.8 kg, 9 kg, 22.5 kg, and 45 kg. ✅ **Testing & Certification:** Cylinders must comply with IS 7285 and undergo hydrostatic testing every 5 years. ✅ **Storage Condition:** Keep upright, away from heat sources, and secured properly. ✅ **Handling Precaution:** Avoid exposure to high temperatures to prevent bursting. --- ### **3. Foam (AFFF – Aqueous Film Forming Foam, AR-AFFF)** ✅ **Packaging:** Available in **HDPE drums, plastic jerry cans, or bulk storage tanks**. ✅ **Standard Packaging Sizes:** 10 L, 20 L, 50 L, 200 L drums. ✅ **Storage Condition:** Store in a cool, ventilated area. Avoid freezing temperatures. ✅ **Shelf Life:** Typically 5 years (verify with the manufacturer). --- ### **4. Water (Stored Pressure & Gas Cartridge Type)** ✅ **Packaging:** Clean, non-corrosive stainless steel or plastic-lined cylinders. ✅ **Refilling Process:** Use fresh, clean, potable water only. ✅ **Storage Condition:** Protect from freezing temperatures. --- ### **5. Clean Agent (HFC-227ea, FK-5-1-12, etc.)** ✅ **Packaging:** Stored in **pressurized cylinders** with appropriate valves. ✅ **Cylinder Capacity:** 2 kg